加热器使用 Use of fan heater

  接通电源

  调节温度开关至所需温度。当环境温度达到设定温度时, 温控器会自动关闭加热装置。 当环境温度低于设定温度一定温差时,温控器会自动打开加热装置开关

  Connect the power

  Adjust the thermostat to set the target temperature. when the environment                 temperature reach the target temperature, the thermostat will turn off the heating       elements. When the environment’s temperature is some degrees lowers than the set target temperature, the thermostat will automatically turn on the heating elements.

  电气接口: 自带15m 4*2.5耐低温电缆线, 链接690v/50Hz三相供电

 

6.  温度调节开关 Adjustable thermostat switch

  该加热器温度调节开关为可调式液体膨胀式温控, 温度可调范围为 0~40℃。

  该温度调节开关也可作为手动调试开关使用。将温度设置调到最大值, 如果环境温度不 超过 30℃时,加热器将会开始正常工作

  The  adjustable  thermostat  switch  is  an  adjustable  liquid  swell  thermostat,  the

temperature range is 0~40

  The adjustable thermostat is also can be used as manual on/off switch. Set the target temperature to the maximum, if the environment temperature is lower than 30, the fan heater will start to work.

 

7. 过热保护装置 Overheat protection device

该暖风机的过热保护装置为液体膨胀式温控, 通常设置过热保护温度为 85±3℃。当因加 热器出现异常导致温度过热时,电路将会被切断。当温度降到安全温度时, 加热器将会 自动重新加热。

The overheat protection device is a liquid swell thermostat, the overheat protection temperature is normally 85±3℃.When there is an overheat due to there is some wrong with the fan  heater, the  overheat  protection  device will  cut the  power of heating elements.  When  the  temperature  lower  to  the  safe  temperature,  the  overheat protection device will automatically turn on the heating elements again.

8. 保养和维修 Maintenance and repair

应该由专业人员每年对暖风机检查和维护一次,包括检查暖风机工作是否正常,清除加 热器风机和管道内灰尘。

There  should  be  professionals  check  and  maintain  the  fan  heater  once  a  year, including checking if the operation of fan heater is proper, cleaning the dust on motor

 

and in the tunnel.

 

问题

可能的原因

解决建议

加热器整机不工作

电源未接通

环境温度已达到或超过设置温度 温控器损坏

电热管损坏

检查或重新连接电源

重新设置目标温度

更换温控器

更换电热管

电机不启动

电机损坏

风叶卡住不运转

单根电热管损坏

更换电机

检查并修复风叶问题

更换电热管

 

 

wrongs

Possible cause

suggestion

Fan     heater

don’t   work

  Power is off

  Environment temperature is over the target temperature

  Thermostat damaged

  Heating elements damaged

  Check or connect the power again

  Reset the target temperature

  Change thermostat

  Change heating elements

Motor    don’t

work

  Motor damaged

  Fan blade is locked

  Some heating element damaged

  Change motor

  Check and repair the lock

  Change heating elements